158 Publication 2711-UM014G-EN-P - September 2008
Chapter 9 Installing the PV600 Terminal
Install the PV600 in a Panel
To install the PV600 terminal in a panel:
1. Cut an opening in the panel by using the panel cutout template
provided with the terminal and remove any sharp edges or
burrs.
2. Make sure the terminal sealing gasket is properly positioned on
the terminal, particularly around the mounting studs as shown.
This gasket forms a compression type seal. Do not use sealing
compounds.
Although the keypad legend strip can be installed on the keypad
and keypad & touch screen terminals at any time, we
recommend that you install the strip after the terminal is
installed.
3. Place the terminal in the panel cutout.
ATTENTION
Disconnect all electrical power from the panel before making the
cutout.
Make sure the area around the panel cutout is clear.
Do not allow metal cuttings to enter any components that may
already be installed in the panel.
Failure to follow this warning may result in personal injury or damage
to the panel components.
Sealing Gasket