Publication 2711P-UM001J-EN-P - November 2009 143
Install and Replace Components Chapter 6
Compatibility After Upgrade
FactoryTalk View ME terminals are compatible with .MER applications
that are the same or a previous version. For example, FactoryTalk
View ME 3.20 terminals can run .MER applications for FactoryTalk
View ME software, versions 3.0, 3.10, and 3.20.
For PanelView Plus CE devices, the appropriate changes are made to
the OS, from Windows CE software, version 3.0 to 4.1, when
upgrading from FactoryTalk View ME software, version 3.0 to 3.10 or
later.
Install RAM or Internal
CompactFlash
The logic module of the 700 to 1500 terminals is available with or
without RAM and internal CompactFlash installed. If ordered as
separate components, you must install the memory before attaching
the logic module to the display module. The internal CompactFlash
contains flash memory, FactoryTalk View ME software, and the
operating system for CE devices.
Follow these steps to install or replace RAM or internal CompactFlash.
1. Remove power from the terminal.
2. Place the terminal, display side down, on a flat stable surface.
3. Loosen the six captive screws that secure the logic module.
4. Carefully lift the logic module away from the terminal and turn
over to expose the circuit board.
Skip steps 5 and 6 if not replacing RAM.
ATTENTION
Wear a properly grounded ESD wristband before
touching any of the electronic components in the
logic module.