6Ć4
AutoMax Processor Module instruction manual (JĆ3650)
for additional information.
M/N 57C404 Network Module
If
you are adding a Network module, you will be prompted
for a Network" name in addition to the drop number and
depth parameters specified in the Network module
instruction
manual. The Network is a single letter code
that
serves as the name for the network.
M/N 57C440 Ethernet Module
I
f y
ou are adding a
n E
thernet module
, y
ou will b
e p
rompted
for a logica
l s
lo
t n
umbe
r (
the actua
l s
lots wher
e M
ultibus will
access th
e m
odule
) w
he
n y
ou add th
e m
odule to a physical
slot
i
n t
h
e r
ack
. T
h
e l
ogica
l
slot
" i
s e
ithe
r 2 a
n
d 3 o
r 4 a
n
d 5
.
Two
s
lots ar
e n
eeded because th
e m
odul
e h
a
s 1
28K of
memor
y a
n
d e
ac
h l
ogical rack slot can acces
s o
nl
y 6
4K.
Note that there ar
e e
xplicit restrictions about slot locatio
n i
n
th
e E
thernet modul
e m
anual.
M/N 57C413 Common Memory Module (128K)
M/N 57C423 Common Memory Module (256K)
A Common Memory module can be added to slot 0 in the
rack, where it provides storage for common memory
variables and bus arbitration for multiple Processor
modules.
If M/N 57C413 is being used, slot 1 must
contain
a Processor module, an Ethernet module (configured to
use logical slots 2Ć3 or 4Ć5), or be empty, because 2
logical slots are required by the Common Memory
module. If M/N 57C423 is being used, slots 1Ć3 must
contain Processor modules, an Ethernet module
(configured to use logical slots 4Ć5), or be empty because
4 logical slots are required by the M/N 57C423 Common
Memory module.
Either version of the Common Memory module can be
used
in other evenĆnumbered slots in the rack for memory
storage, but in this case it must be added to the rack as
two
M/N GEN32K generic modules (see section 6.3). Note
that M/N 57C423 provides 128K of memory storage, the
same as M/N 57C413, when used in an evenĆnumbered
slot.
M/N 57C416 Remote I/O Interface Module
See section 6.2 for additional information required to
configure the remote I/O system after you have added the
Remote I/O module.
Foreign Module or Other Unsupported Module
If
the module you want to add is not supported, i.e., not on
the list of available modules, see section 6.3.
M/N 57C418 AB Interface Module or
M/N 57C417 AutoMate Interface Module
If you are adding an AB Interface module or AutoMate
Interfac
e m
odule
, y
o
u s
houl
d e
nter th
e d
ro
p n
umber as a
decimal value
. (
Th
e s
am
e d
ecima
l n
umber must be
physicall
y s
et o
n t
h
e f
aceplat
e o
n t
he actual module.
) T
he
module wil
l c
onvert switc
h s
ettings to octal value
s i
nternally.
M/N 57C429 RĆNet Network Interface Module
If you are adding an RĆNet Interface module, you must
enter the node number as a hexadecimal value. (The
Comentarios a estos manuales