Adapter Parameters B-3
09 [DPI I/O Active]
I/O that the adapter is actively transmitting. The
value of this parameter will usually be equal to the
value of Parameter 8 - DPI I/O Config.
Default: xxx0 0001
Bit Values: 0 = I/O disabled
1 = I/O enabled
Type: Read Only
Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used
10 [Flt Cfg Logic]
Sets the Logic Command data that is sent to the
drive if any of the following is true:
Parameter 06 - [Comm Flt Action] is set to
Send Flt Cfg and communications are
disrupted.
The bit definitions will depend on the product to
which the adapter is connected.
Default: 0000 0000 0000 0000
Minimum: 0000 0000 0000 0000
Maximum: 1111 1111 1111 1111
Type: Read/Write
Reset Required: No
11 [Flt Cfg Ref]
Sets the Reference data that is sent to the drive if
any of the following is true:
Parameter 06 - [Comm Flt Action] is set to
Send Flt Cfg and communications are
disrupted.
Default: 0
Minimum: 0
Maximum: 4294967295
Type: Read/Write
Reset Required: No
Important: If the drive uses a 16-bit
Reference, the most significant word of this
value must be set to zero (0) or a fault will
occur.
12
13
14
15
16
17
18
19
[Flt Cfg A1]
[Flt Cfg A2]
[Flt Cfg B1]
[Flt Cfg B2]
[Flt Cfg C1]
[Flt Cfg C2]
[Flt Cfg D1]
[Flt Cfg D2]
Sets the data that is sent to the Datalink in the
drive if any of the following is true:
Parameter 06 - [Comm Flt Action] is set to
Send Flt Cfg and the communications are
disrupted.
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Minimum: 0
Maximum: 4294967295
Type: Read/Write
Reset Required: No
Important: If the drive uses 16-bit
Datalinks, the most significant word of this
value must be set to zero (0) or a fault will
occur.
20 PIDD W0 Cfg
Configured Process Input Data Description for
Word 0. PCP Object to use for Word 0 transmitted
to Interbus master.
Default: 0x2F9A
(Logic Status)
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
21 PIDD W0 Actual
Actual Process Input Data Description for Word 0.
Value: See Ta b l e B. 1
Type: Read Only
Parameter
No. Name and Description Details
Bit
Default
10000xxx
01234576
20COMM-UM007A-EN-P.book Page 3 Tuesday, January 22, 2002 10:52 AM