B-4 Adapter Parameters
22 PIDD W1 Cfg
Configured Process Input Data Description for
Word 1. PCP Object to use for Word 1 transmitted
to Interbus master.
Default: 0x2F9B
(Feedback)
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
23 PIDD W1 Actual
Actual Process Input Data Description for Word 1.
Value: See Ta b l e B . 1
Type: Read Only
24 PIDD W2 Cfg
Configured Process Input Data Description for
Word 2. PCP Object to use for Word 2 transmitted
to Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
25 PIDD W2 Actual
Actual Process Input Data Description for Word 2.
Value: See Ta b l e B . 1
Type: Read Only
26 PIDD W3 Cfg
Configured Process Input Data Description for
Word 3. PCP Object to use for Word 3 transmitted
to Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
27 PIDD W3 Actual
Actual Process Input Data Description for Word 3.
Value: See Ta b l e B . 1
Type: Read Only
28 PIDD W4 Cfg
Configured Process Input Data Description for
Word 4. PCP Object to use for Word 4 transmitted
to Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
29 PIDD W4 Actual
Actual Process Input Data Description for Word 4.
Value: See Ta b l e B . 1
Type: Read Only
30 PIDD W5 Cfg
Configured Process Input Data Description for
Word 5. PCP Object to use for Word 5 transmitted
to Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
31 PIDD W5 Actual
Actual Process Input Data Description for Word 5.
Value: See Ta b l e B . 1
Type: Read Only
32 PIDD W6 Cfg
Configured Process Input Data Description for
Word 6. PCP Object to use for Word 6 transmitted
to Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
33 PIDD W6 Actual
Actual Process Input Data Description for Word 6.
Value: See Ta b l e B . 1
Type: Read Only
34 PIDD W7 Cfg
Configured Process Input Data Description for
Word 7. PCP Object to use for Word 7 transmitted
to Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
Parameter
No. Name and Description Details
20COMM-UM007A-EN-P.book Page 4 Tuesday, January 22, 2002 10:52 AM