H-2
2-Axis Servo Module M/N 57C422B
where:
nnnnn - BASIC statement number. This number may range
from 1-32767.
SYMBOLIC_NAME! - A symbolic name chosen by the user
and ending with (!). This indicates a LONG INTEGER data
type and all references will access registers "r" and "r+ 1 ".
SYMBOLIC_NAME% - A symbolic name chosen by the user
and ending with (%). This indicates an INTEGER data type
and all references will acces register “r”.
SYMBOLIC_NAME@ - A symbolic name chosen by the
user and ending with (@). This iridicates a BOOLEAN data
type and all references will access bit number "b" in register
"r."
SLOT - Slot number that the module is plugged into. This
number may range from 0-15.
REGISTER - Specifies the register that is being referenced.
This number may range from 0-4095.
BIT - Used with boolean data types only. Specifies the bit in
the register that is being referenced. This number may range
from 0-15.
Sample Configuration Task
The following is a sample configuration for the X axis of a
module located in slot 8. Note that version 3.0 or later
Programming Executive software allows you to enter the
variable names and comments below on a customized form
and does not require a separate task.
1000 IODEF ENCODER_SETUP%[ SLOT =8, REGISTER=0]
1010 IODEF DRIVE_SETUP%[ SLOT =8, REGISTER=1]
1020 IODEF SWITCHES%[ SLOT =8, REGISTER=2]
1030 IODEF PGAIN%[ SLOT =8, REGISTER=3]
1040 IODEF IGAIN%[ SLOT =8, REGISTER=4]
1050 IODEF VGAIN%[ SLOT =8, REGISTER=5]
1060 IODEF FGAIN%[ SLOT =8, REGISTER=6]
1070 IODEF DBCOMP%[ SLOT =8, REGISTER=7]
1080 IODEF MAX_FOLL_ERR%[ SLOT =8, REGISTER=8]
1090 IODEF MAX_VEL_ERR%[ SLOT =8, REGISTER=9]
1100 IODEF IN_TOLERANCE%[ SLOT =8, REGISTER=10]
1110 IODEF HOME_SPDI[ SLOT =8, REGISTER=15]
1120 IODEF CMD_POSI[ SLOT =8, REGISTER=17]
1130 IODEF CMD_VELI[ SLOT =8, REGISTER=19]
1140 IODEF CMD_ACC![ SLOT =8, REGISTER=21]
1150 IODEF CMD_DECI[ SLOT =8, REGISTER=23]
1160 IODEF GEAR_RATIO![ SLOT =8, REGISTER=25]
1170 IODEF MAX_VOLTS%[ SLOT =8, REGISTER=31]