Rockwell-automation 57C620 AutoMax Programming Executive Version 3.8 Manual de usuario Pagina 64

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 298
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 63
5Ć8 AutoMax Programming Executive Version 3.x
are transferring systems in, enter the system names
separated by commas or spaces. (R)
SystemĆwide information only Ć If this box is selected, only
the
system, section, rack, and network databases, and the
system documentation file will be transferred.
Step 4. Select which of the following groups of files you want to
transfer with the system. These files are not necessary
since they can be regenerated from the source files.
Object files Ć the compiled application tasks, parameter
object files, and rack configuration object file(s).
CrossĆreference files
Transfer Tokens (See Appendix N for more information.)
Step 5. Select Help for information about the transfer procedure,
Cancel to return to the System Configurator without
transferring a system, or OK to begin the system transfer.
Figure 5.4 Ć T
ransfer System
 
You can import a system created with the AutoMax Software
Designer (ASD) V
ersion 8.x (M/N 57C310Ć57C313) into the AutoMax
Executive
software. The system must not already exist in the AutoMax
Executive software. This procedure does not delete, or alter in any
way, the original ASD system.
The Import procedure will add the system, sections, and racks using
information stored in the ASD file. One section is created for each
network, and all of the racks named with that network's letter are
stored in that section. If a rack is connected to more than one
network, the primary" network is used. The rack's name in ASD (for
Vista de pagina 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 297 298

Comentarios a estos manuales

Sin comentarios