Rockwell-automation 1203-EN1 EtherNet/IP-to-SCANport Module Manual de usuario Pagina 121

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 186
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 120
EtherNet/IP Objects C-11
Class Code
Instances
The number of instances depends on the number of groups in the device.
A group of module parameters is appended to the list of groups in the
device. The total number of groups can be read in Instance 0, Attribute 2.
Class Attributes
Parameter Group Object
Hexadecimal Decimal
0x10 16
Number Description
0 Class Attributes
1 Drive Group 1 Attributes
n Last Drive Group Attributes
n + 1 Module Group Attributes
Attribute
ID
Access
Rule Name
Data
Type Description
1 Get Parameter group
version
UINT 1
2 Get Max Instance UINT Total number of groups
8 Set Native Language USINT 0 = English
1 = French
2 = Spanish (Mexican)
3 = Italian
4 = German
5 = Japanese
6 = Portuguese
7 = Mandarin Chinese
8 = Russian
9 = Dutch