F-2 Supported Emulated Block Transfer Commands
The following table lists the supported emulated block transfer
commands and where you can find more information on them.
When an operation is unsuccessful, header word 1 of the drive response
contains a negative value (bit 15 = 1).
If an error occurs, the drive also returns a status word to indicate the
reason for the failure. The location of the status word is typically header
word 3 in the drive response, but will depend on the message.
Figure F.1 Example Message Structure and Error Message Reply
Supported Emulated Block Transfer Commands
Command
Page Command Page
Parameter Value Read
(1)
(1)
This function can be accessed in the module and product. The following examples
describe how to access it in the product. To do so in the module, add 16384 to the
decimal value of header word 2.
F-3
NVS Functions F-16
Parameter Value Write
(1)
F-4 Fault Command Write
(1)
F-17
Parameter Read Full
(1)
F-6 Fault Queue Entry Read Full
(1)
F-18
Product ID Number Read
(1)
F-9 Fault Queue Size
(1)
F-20
Scattered Parameter Value Read F-11 Trip Fault Queue Number
(1)
F-22
Scattered Parameter Value Write F-13
Emulated Block Transfer Status Word
Header 1
PLC Request
Header Word 0
Header Word 1
Header Word 2
Message Length
Drive Response
Header 2
Data Word 3
Data
Header 1 OR 0x8000
Header Word 0
Header Word 1
Header Word 2
Message Length
Header 2
Header Word 3
Error Code