Rockwell-automation 1746-HSCE2 Multi-Channel High Speed Counter Module Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 140
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
Publication 1746-UM002B-EN-P - August 2004
2-18 Module Operation
OP MODE: Operating Mode Bits
The module uses these two bits to tell the processor what mode it is
in. In class 1, the data value that an input word contains changes
based on the operating mode.
Table 2.2 Mode Bit Settings
Output State Byte
These bits correspond to the real or virtual state of the outputs. Bits 00
through 03 represent real outputs. Bits 04 through 07 represent virtual
outputs.
Counter Status Bytes
Each counter has an associated status byte. The format of the byte
depends on the module’s class of operation as shown below.
Figure 2.14 Class 1 Counter Status Byte Format
Figure 2.15 Class 4 Counter Status Byte Format
Bit 09 Bit 08 Mode
00Reserved
0 1 Mode 1
1 0 Mode 2
1 1 Mode 3
15 14 13 12 11 10 09 08
07 06 05 04 03 02 01 00
C/R
0 ROvF RUdF COvF CUdF CState
15 14 13 12 11 10 09 08
07 06 05 04 03 02 01 00
0 0 ROvFRUdFCOvFCUdF CState