Formatting Module Data (WRITES)
Chapter 7
733
Figure 7.43
Command
Block W
ord Assignments
50085
WORD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Axis control word 1
Axis control word 2
(MS) Setpoint 13 position
(LS) Setpoint 13 position
Setpoint 13 velocity
Setpoint 13 acceleration
Setpoint 13 deceleration
Axis control word 1
Axis control word 2
(MS) Setpoint 13 position
(LS) Setpoint 13 position
Setpoint 13 velocity
Setpoint 13 acceleration
Setpoint 13 deceleration
Axis 1
Axis 2
Axis Control Word 1 (words 1 and 8)
The structure of axis control word 1 is shown below:
Figure 7.44
Axis
Control W
ord 1
50086
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
10
Start
.
.
.
.
.
.
..
.
Control
word ID
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
1
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
Readout select:
00 = Position
01 = Following Error
10 = Diagnostic
Integral Disable
Reset
Immediate stop
Slide stop Jog reverse
Jog forward
Jog rate (1 = high, 0 = low)
Incremental move 13
Auto/manual
Hardware
start enable