Command Block
Appendix E
E2
Figure E.2
Axis
Control W
ord 1 (words 1 and 8)
50086
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
10
Start
.
.
.
.
.
.
..
.
Control
word ID
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
1
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
Readout select:
00 = Position
01 = Following Error
10 = Diagnostic
Integral Disable
Reset
Immediate stop
Slide stop Jog reverse
Jog forward
Jog rate (1 = high, 0 = low)
Incremental move 13
Auto/manual
Hardware
start enable
Figure E.3
Axis
Control W
ord 2 (words 2 and 9)
50087
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
0, Setpoint (1 to 13) or
000000000
Motion segment (14 to 127),
binary format