Installing the Linear Positioning Module
Chapter 5
513
Make sure that the voltage driving each input is at the appropriate level.
Figure 5.8 shows the discrete input connections.
Figure 5.8
Discrete
Input Connections
50049
Auto/Manual
Wiring Arm
Terminals
14
16
18
20
22
24
26
28
LOOP 2
13
15
17
19
21
23
25
27
LOOP 1
Belden 8761 or equivalent (50 ft. max.)
15 to 24 VDC
Discrete Input
Supply
(Customer
Supplied)
- +
Start
Use any number of
Estop switches in series
Jog Forward
Jog Reverse
Input 1
Input 2
AUTO/MAN
START
STOP
JOG FWD
JOG REV
INPUT 1
INPUT 2
I/P COMMON
AUTO/MAN
START
STOP
JOG FWD
JOG REV
INPUT 1
INPUT 2
I/P SUPPLY
Auto/Manual
Start
Use any number of
Estop switches in series
Jog Reverse
Input 1
Input 2
Jog Forward
2
2
2
2
If you are driving a discrete input from a discrete output of another module,
keep in mind that you must measure the output voltage at the discrete output
itself and not at the discrete output power supply. There is a 1.6 VDC drop
between the power supply and the discrete output at maximum current. To yield
the minimum 10 VDC at the discrete output, the discrete output supply must be
greater than 11.6 VDC.