100 Rockwell Automation Publication 1734-UM017B-EN-P - October 2013
Appendix B Adapter Web Dialogs
Subnet Mask
Gateway Address
Primary Name Server
Secondary Name Server
Domain Name
For Ethernet Link, select from these choices:
Autonegotiate Status
- Autonegotiate Speed and Duplex
- Force Speed and Duplex
Select Port Speed - 10 megabits, 100 megabits
Select Duplex Mode - Half Duplex, Full Duplex
3. From the Network Configuration page, click Apply Changes to save the
modified values.
Use the Services Page
To use the Services page to change the password for the Configuration web page
or disable the web server, complete these procedures.
1. Click Services from the tab at the top of the page or panel on the left.
The Services page opens.
2. From the Services page, make these entries.
Click in the Enable box to change whether the web server runs after the
module is reset.
IMPORTANT
If there is a mismatch in duplex between the adapter and the
connected equipment you may experience 'intermiittent
connectivity.' For complete details and information on how to
resolve this, refer to publication ENET-A003
.