68 Rockwell Automation Publication 1769-UM006E-EN-P - July 2013
Chapter 4 Module Configuration, Output, and Input Data
35
Not used Lin-
ear
Not used Counter 2
Configuration Flags
36 Ctr3MaxCount Counter 3 Maximum
Count
37
38 Ctr3MinCount Counter 3 Minimum
Count
39
40 Ctr3Preset Counter 3 Preset
41
42 Ctr3Hysteresis Counter 3 Hysteresis
43 Ctr3Scalar Counter 3 Scalar
44 Ctr3CyclicRateUpdateTime Counter 3 Cyclic Rate
Update Time
45
Not used Lin-
ear
Not used Counter 3
Configuration Flags
46 Range0To11[0].HighLimit Range 0 High Limit
47
48 Range0To11[0].LowLimit Range 0 Low Limit
49
50 Out
15
Out
14
Out
13
Out
12
Out
11
Out
10
Out
09
Out
8
Out
7
Out
6
Out 5 Out 4 Out
3
Out 2 Out
1
Out
0
Range 0 Output Control
51
Not used Inv Not used Type Not used ToThisCtr Range 0 Configuration
Flags
52 Range0To11[1].HighLimit Range 1 High Limit
53
54 Range0To11[1].LowLimit Range 1 Low Limit
55
56 Out
15
Out
14
Out
13
Out
12
Out
11
Out
10
Out
09
Out
8
Out
7
Out
6
Out 5 Out 4 Out
3
Out 2 Out
1
Out
0
Range 1 Output Control
57
Not used Inv Not used Type Not used ToThisCtr Range 1 Configuration
Flags
58 Range0To11[2].HighLimit Range 2 High Limit
59
60 Range0To11[2].LowLimit Range 2 Low Limit
61
62 Out
15
Out
14
Out
13
Out
12
Out
11
Out
10
Out
09
Out
8
Out
7
Out
6
Out 5 Out 4 Out
3
Out 2 Out
1
Out
0
Range 2 Output Control
63
Not used Inv Not used Type Not used ToThisCtr Range 2 Configuration
Flags
64 Range0To11[3].HighLimit Range 3 High Limit
65
Table 12 - Configuration Array - 1769-HSC Module and CMX 5370 L2 Packaged Controller Embedded HSC (Continued)
Word
Bit
Function
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00