Motor Starter Operation B-5
Publication 198-UM002A-EN-P December 2001
Inverter Type Distributed Starter I/O Assemblies
These assemblies are available when the Motor Starter Type parameter is set to the value 3 =
Inverter Starter.
Inverter Type Distributed Starter Output (Consumed) Assemblies
Instance 3 is the required output (consumed) assembly defined in the DeviceNet Motor
Starter Profile.
Instance 154 is the default output (consumed) assembly for Inverter Type Distributed Starters
Inverter Type Distributed Starter Input (Produced) Assemblies
Instance 52 is the required input (produced) assembly defined in the DeviceNet Motor Starter
Profile.
Instance 155 is the default input (produced) assembly for Inverter Type Distributed Starters
Distributed Starter Specific DeviceNet Objects
When a Cat. No. 198-DNG is programmed to present itself as a Distributed Starter on
DeviceNet, two start-specific objects become visible via DeviceNet. These two objects are
Table B.5 Instance 153 — Default Produced Reversing Distributed Starter
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Location 1 Location 0 Status 6 Status 5 Status 4 Status 3 Status 2 Status 1
1 Error 6 Error 5 Error 4 Error 3 Error 2 Error 1 Error 0 Location 2
2 Input 8 Input 7 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1
3 Input 16 Input 15 Input 14 Input 13 Input 12 Input 11 Input 10 Input 9
4 Input 24 Input 23 Input 22 Input 21 Input 20 Input 19 Input 18 Input 17
Table B.6 Instance 154 — Default Consumed Inverter Type Distributed Starter
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Output 8 Output 7 Output 6 Preset 2 Preset 1 Preset 0 Run Rev Run Fwd
1 Output 16 Output 15 Output 14 Output 13 Output 12 Output 11 Output 10 Output 9
Table B.7 Instance 155 — Default Produced Inverter Type Distributed Starter
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Location 1 Location 0 Status 6 Status 5 Status 4 Status 3 Status 2 Status 1
1 Error 6 Error 5 Error 4 Error 3 Error 2 Error 1 Error 0 Location 2
2 Input 8 Input 7 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1
3 Input 16 Input 15 Input 14 Input 13 Input 12 Input 11 Input 10 Input 9
4 Input 24 Input 23 Input 22 Input 21 Input 20 Input 19 Input 18 Input 17