Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Manual de usuario Pagina 110

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 109
Publication 2098-RM003A-EN-P October 2001
2-94 Command Reference
Motor Encoder Interpolation
Format: :aa0EDfddcc<cr>
Parameter
Code:
0x0ED
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dd Interpolation from lines to counts of a sine/cosine
encoder, where:
0 = x4
1 = x8
2 = x16
3 = x32
4 = x64
5 = x128
6 = x256
7 = x512
8 = x1024
Minimum
Value:
0x00
Maximum
Value:
0x08
Default: 0x06