Publication 2098-RM003A-EN-P October 2001
Command Reference 2-51
Overtravel Commands
Positive Soft Position Limit
Negative Soft Position Limit
Format: :aa0D8fddddddddcc<cr>
Parameter
Code:
0x0D8
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddddddd Position that, when exceeded positively, will cause a
deceleration to zero velocity.
Minimum
Value:
0x80000001
Maximum
Value:
0x7FFFFFFF
Default: 0x7FFFFFFF
Format: :aa0D9fddddddddcc<cr>
Parameter
Code:
0x0D9
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x06 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields: dddddddd Position that, when exceeded negatively, will cause
a deceleration to zero velocity.
Minimum
Value:
0x80000001
Maximum
Value:
0x7FFFFFFF
Default: 0x80000001