Publication 2098-RM003A-EN-P October 2001
2-4 Command Reference
Boot Firmware Version
Reset User Parameters to Factory Defaults
Drive Name
Format: :aa003fvvrrcc<cr>
Parameter
Code:
0x003
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: vv
rr
Major boot firmware version.
Minor boot firmware revision.
Format: :aa004fcc<cr>
Parameter
Code:
0x004
Valid Function
Codes:
0x1 = Write Working Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x06 = Command Disabled when Drive is Enabled
0x08 = Invalid Function Code
Data Fields: None
Format: :aa006fddddcc<cr>
Parameter
Code:
0x006
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x08 = Invalid Function Code
Data Fields: dddd Drive name, a 64-character string.
Default: " "