Publication 2098-RM003A-EN-P October 2001
Command Reference 2-65
Motor Resistance
Motor Inductance
Format: :aa03Dfddddcc<cr>
Parameter
Code:
0x03D
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x04 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields: dddd Phase-phase stator resistance, in units of Ohms *
256.
Minimum
Value:
0x0001
Maximum
Value:
0xFFFF
Default: 998
Format: :aa03Efddddcc<cr>
Parameter
Code:
0x03E
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x04 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields: dddd Phase-phase stator inductance, in units of
milliHenries * 256.
Minimum
Value:
0x0001
Maximum
Value:
0xFFFF
Default: 6144