Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Manual de usuario Pagina 93

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 92
Publication 2098-RM003A-EN-P October 2001
Command Reference 2-77
Maximum Linear Speed
Format: :aa0E6fddddcc<cr>
Parameter
Code:
0x0E6
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddd Maximum speed of a linear motor, in units of
meters/sec * 256.
Minimum
Value:
32
Maximum
Value:
0x7FFF
Default: 256
Vista de pagina 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 175 176

Comentarios a estos manuales

Sin comentarios