Publication 2098-RM003A-EN-P October 2001
Command Reference 2-55
Homing Type
Format: :aa0C5fddcc<cr>
Parameter
Code:
0x0C5
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dd Homing type code, where:
0x00: Home to sensor, forward to marker
0x01: Home to marker
0x02: Home to sensor
0x03: Home to sensor, backward to marker
0x04: Home to current setting
0x05: Home to current setting, backward to marker.
Minimum
Value:
0x00
Maximum
Value:
0x03
Default: 0x00