Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Manual de usuario Pagina 91

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 90
Publication 2098-RM003A-EN-P October 2001
Command Reference 2-75
Motor Mass
Total Moving Mass
Format: :aa0E4fddddddddcc<cr>
Parameter
Code:
0x0E4
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields: dddddddd Mass of the moving part of a linear motor, in units of
Kg*65536.
Minimum
Value:
0x00000001
Maximum
Value:
0x7FFFFFFF
Default: 0x00010000
Format: :aa11Ffddddddddcc<cr>
Parameter
Code:
0x11F
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields: dddddddd Total moving mass of a linear motor system, in units
of Kg*65536.
Minimum
Value:
0x00000001
Maximum
Value:
0x7FFFFFFF
Default: 0x00010000
Vista de pagina 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 175 176

Comentarios a estos manuales

Sin comentarios