Rockwell-automation 20D PowerFlex 700S with Phase I Control Reference Manual de usuario Pagina 141

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 190
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 140
Rockwell Automation Publication PFLEX-RM002D-EN-E - August 2013 141
Detail Drive Configuration and Operation Chapter 1
Table 9 - Encoder Sample Interval Settings
[Encdrx Error] indicates the error status of the encoder when there is an error.
The bits for [Encdrx Error] are broken down as follows:
Bit 0 - “EncdrMissing
Bit 1 - “Quad Loss
Bit 2 - “Phase Loss”
Bit 3 - “Phase Level”
The encoder block generates speed feedback, seen in [Encdrx Spd Fdbk].
[Encdrx Spd Fdbk] is in units of RPM.
The encoder block also generates a position feedback, seen in [Encdrx Position].
[Encdrx Position] is in counts.
Bit 15 14 13 12 Encoder Sample Interval Settings
00000.5 ms
00010.5 ms (min. setting)
00101.0 ms
00111.5 ms
01002.0 ms (default setting)
01012.5 ms
01103.0 ms
01113.5 ms
10004.0 ms
10014.5 ms
10105.0 ms
10115.5 ms
11006.0 ms (max. setting)
11016.0 ms
11106.0 ms
11116.0 ms
231
230
233
232
234
Encoder 0
Processing
Encdr0 Spd Fdbk
Encdr0 Position
Encdr0 ErrorEncoder0 PPR
Encdr0 Config
Vista de pagina 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 189 190