Rockwell Automation Publication PFLEX-RM002D-EN-E - August 2013 147
Detail Drive Configuration and Operation Chapter 1
Parameter 267 [Reslvr0 Status] indicates status of the resolver option card port 0.
Bit 0 “Cable Statusindicates that the cable tuning test is in progress.
Bit 1 “Tune Result” indicates the tuning parameter type. When set, it
indicates the tuning is using the parameter database. When cleared, it
indicates the tuning is using derived data.
Bit 2 “Mtr Turning” indicates that the motor is turning.
Bit 3 “Cable Comp
Bit 4 “Energized” indicates the resolver is energized.
Bit 8 “Open Wire” indicates a problem with the cable (open circuit).
Bit 9 “Power Supply” indicates problem with the option card's power
supply.
Bit 10 “Diag Fail” indicates the option card has failed its power-up
diagnostics.
Bit 11 “Select OK”
Motor Position Feedback
The motor position feedback is selected according to the feedback device
selection. The value for motor position feedback appears in parameter 762 [Mtr
Posit Fdbk]. [Mtr Posit Fdbk] is in counts. From there, the position feedback
enters the position control loop.