44 Rockwell Automation Publication PFLEX-RM002D-EN-E - August 2013
Chapter 1 Detail Drive Configuration and Operation
[DigIn 2 Sel] can be set to the following values:
[DigIn 3 Sel] can be set to the following values:
[DigIn x Debounce] sets a delay time to allow any bounce in the digital input to
settle out. This parameter has a range of 0 to 15.5 milliseconds.
When [DigIn x Sel] is set to “User Select,” the function of the digital input is
determined by the following:
[DigIn x Data] determines any bits that should be permanently set. [DigIn
x Data] sets the value of [DigIn x User Data] except for the bit chose in
[DigIn x Bit]
[DigIn x Data] determines the bit you wish to toggle based on whether the
digital input is on or off
Value Description Value Description
0 “Not Used” 14 “Normal Stop”
1 “Enable 15 “Spd Ref Sel1”
2 “Clear Faults” 16 “Spd Ref Sel2”
3 “Ext Fault” 17 “Spd Ref Sel3”
4 “Norm Stop-CF” 18 “CurLim Stop”
5“Start 19Coast Stop
6 “Reverse 21 “BscIndx Step”
7 “Run 22 “BscIndxStpRv”
8“Fwd/Reverse 26PI Trim En
9 CurLim Stop 29 Trend Trig
10 Jog 1” 30 “PreCharge En
11 Aux Fault” 31 “Regis 1 Ltch
12 AuxFault Inv” 32 “+Hrd OvrTrvl”
13 Jog 2” 33 “-Hrd OvrTrvl”
Value Description Value Description
0 “Not Used” 9 “CurLim Stop”
1“Normal Stop 10Coast Stop
2 “Start” 11 Aux Fault”
3“Run 12AuxFault Inv
4 “Clear Faults” 13 “User Select”
5 “Stop-CF” 23 “Logix Motion”
6 Jog 1” 24 “+Hrd OvrTrvl”
7 Jog 2” 25 “-Hrd OvrTrvl”
8“Fwd/Reverse