Rockwell Automation Publication PFLEX-RM002D-EN-E - August 2013 85
Detail Drive Configuration and Operation Chapter 1
where:
where:
Solving for the lowest common denominator, the 1024s on the top and bottom
cancel out so that:
Therefore, parameter 745 [PositRef EGR Mul] = 4 and parameter 746 [PositRef
EGR Div] = 1. This will set up the position loop of the follower to move 4 counts
for every 1 count of the master.
[Spd Ref 2 Multi] is calculated:
Notice that the encoder PPRs should not be included in the calculation for
parameter 13 [Spd Ref2 Multi].
[Spd Ref2 Multi] is rounded to the 4th decimal place. The position loop gear
ratios will be exact, so that the follower tracks at 4 times the master's speed.
Position Offset
Offsets can be added to the position reference. Offsets are used to make a
correction move to synchronize the follower to the master position.
PPRm = the PPR of the master encoder
PPRf = the PPR of the follower encoder
Ratiof:Ratiom = the desired ratio between the follower speed and the master speed
CPRf = the counts per revolution of the follower feedback device. For an incremental
encoder this is 4 times the encoder PPR. For a Stegmann Hi-Res encoder this is
1048576. For a Resolver this is 65536.
CPRm = the counts per revolution of the master encoder. For an incremental encoder this is
4 times the encoder PPR. For a Stegmann Hi-Res encoder this is 1048576. For a
Resolver this is 65536.
14096
44096
Div] EGR [PositRef
Mul] EGR [PositRef
==
RatiomCPRm
RatiofCPRf
1
4
Div] EGR [PositRef
Mul] EGR [PositRef
=
4
1
4
]Multi Ref2 Spd[ ===
Ratiom
Ratiof
+
Rate Lim
753
754
755
LPass
Filter
756
Posit Offset 1
Posit Offset 2
Posit Offset Spd
Position Control
(X Offset Pol)
Position Control
(X Offset Ref)
Deriv
Δ
740 04
740 05
741 05
Position Status
(X OffRefActl)
Added to position
reference after
EGR
Vista de pagina 84