Rockwell-automation 1440-DYN02-01RJ XM Dynamic Measurement Module Manual de usuario Pagina 110

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 160
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 109
110 Publication ICM-UM002F-EN-E - March 2013
Appendix B CIP Objects
Instance 199 - Dynamic Assembly
This Assembly instance can be created and configured with the XM
Configuration Tool. Using the configuration software, you determine the
format of the data. This assembly instance can be selected to be sent in
response to an I/O Poll request from a Master.
The Dynamic Assembly can include all of the measurement values included in
Assembly instance 101. In addition, the dynamic Assembly can include the
following configuration parameters.
56 - 59 Channel 0 Vector 1 Magnitude value
60 - 63 Channel 0 Vector 1 Phase value
64 - 67 Channel 1 Vector 1 Magnitude value
68 - 71 Channel 1 Vector 1 Phase value
72 - 75 Channel 0 Vector 2 Magnitude value
76 - 79 Channel 0 Vector 2 Phase value
80 - 83 Channel 1 Vector 2 Magnitude value
84 - 87 Channel 1 Vector 2 Phase value
88 - 91 Channel 0 Vector 3 Magnitude value
92 - 95 Channel 1 Vector 3 Magnitude value
96 - 99 Channel 0 Not 1X value (AIP Object Instance #3)
100 - 103 Channel 1 Not 1X value (AIP Object Instance #4)
104 - 107 SMAX Magnitude value (AIP Object Instance #5)
108 - 111 SMAX Phase value (AIP Object Instance #6)
112 - 115 Channel 0 Sum Harmonics value (AIP Object Instance #7)
116 - 119 Channel 1 Sum Harmonics (AIP Object Instance #8)
120 - 123 Acceleration value
Table B.4 Instance 101 Data Format (Measurement Values Assembly)
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Table B.5 Instance 199 Component Mapping
EPATH (where ii =
instance number)
Class
Name
Class
Number
Instance
Number
Attribute
Name
Attribute
Number
Data
Type
21 1D 03 24 ii 30 04 Alarm 31D
h
1 - 16 AlarmEnable 4 BOOL
21 1D 03 24 ii 30 05 Alarm 31D
h
1 - 16 Type 5 USINT
21 1D 03 24 ii 30 07 Alarm 31D
h
1 - 16 AlarmCondition 7 USINT
21 1D 03 24 ii 30 08 Alarm 31D
h
1 - 16 AlarmHAlertLimit 8 REAL
21 1D 03 24 ii 30 09 Alarm 31D
h
1 - 16 AlarmHDangerLimit 9 REAL
21 1D 03 24 ii 30 0A Alarm 31D
h
1 - 16 AlarmLAlertLimit 10 REAL
Vista de pagina 109