Vista de pagina 32
Publication 1753-PM001A-EN-P - November 2005
Connect to the GuardPLC Controller 1-23
Change the IP Address of
the Controller
After you establish communications with the controller, you can
change the IP address of the controller to match your Ethernet
network. There are two ways to change the IP address of the
controller:
From the Control Panel:
1. Choose Device Settings from the Extra menu.
2. Enter the new IP address.
3. Click OK.
Or follow Step 4: Get Communication Settings on page 1-9 and
Step 5: Change Settings via MAC Address on page 1-10.
TIP
Typically, you change the SRS of the GuardPLC
controller to match that of the controller/routine that
you wish to download to it. Recall that the SRS is
compiled into the executable and ensures that this
.EXE can only be downloaded to a GuardPLC
controller with a matching SRS.
TIP
To re-establish communications with the new IP
address and subnet of your GuardPLC controller, you
may need to change the IP and subnet address of
your programming terminal. Use the Network
section of the Windows Control Panel to change the
programming terminal’s IP address and subnet mask.