Parameters Cross-Referenced by Name
C-3
Flux Current Ref
A129
Advanced Based on Drive
Rating
9-38
Flying Start En
A096
Advanced 0 = Disabled
9-28
Internal Freq
A069
Advanced 0.0 Hz
9-19
IR Voltage Drop
A128
Advanced Based on Drive
Rating
9-38
Jog Accel/Decel
A079
Advanced 10.0 sec
9-21
Jog Frequency
A078
Advanced 10.0 Hz
9-20
Language
A108
Advanced 1 = English
9-31
Maximum Freq
P035
Basic 60 Hz
9-2
Maximum Voltage
A088
Advanced Drive Rated
Volts
9-25
Minimum Freq
P034
Basic 0.0 Hz
9-2
MOP Reset Sel
A162
Advanced 1 = Save MOP
Ref
9-45
Motor NP FLA
A126
Advanced Drive Rated
Amps
9-37
Motor NP Hertz
P032
Basic 60 Hz
9-2
Motor NP Volts
P031
Basic Varies
9-2
Motor OL Current
P033
Basic Varies
9-2
Motor OL Select
A090
Advanced 0 = No Derate
9-25
Opto Out Logic
A064
Advanced 0
9-16
Opto Out1 Level
A059
Advanced 0.0
9-16
Opto Out1 Sel
A058
Advanced 0 = Ready/Fault
9-14
Opto Out2 Level
A062
Advanced 0.0
9-16
Opto Out2 Sel
A061
Advanced 2 = Motor
Running
9-14
Output Current
d003
Display Read Only
9-46
Output Freq
d001
Display Read Only
9-46
Output Power
d022
Display Read Only
9-51
Output Power Fctr
d023
Display Read Only
9-51
Output Torque Current
d029
Display Read Only
9-52
Output Voltage
d004
Display Read Only
9-46
PID Deadband
A138
Advanced 0.0%
9-40
PID Diff Rate
A136
Advanced 0.0 (1/sec)
9-40
PID Feedback Sel
A133
Advanced 0 = 1-10V Input
9-39
PID Integ Time
A135
Advanced 0.0 sec
9-40
Parameter Name No.
Parameter
Group
Default
Value
Page
No.
Comentarios a estos manuales