ControlLogix w/1769-ADN DeviceNet Example Ladder Program 8-17
Figure 8.20 Example ControlLogix Ladder Logic CH2 Subroutine
1769-SM2 Channel 2 Subroutine
The following rungs display some of the Logic Status bits from the drive. Refer to Appendix D in the 1769-SM2 user manual
for additional information about the Logic Status word.
0
SM2_Input_Data[5].0 CH2_Ready
1
SM2_Input_Data[5].1 CH2_Active
2
SM2_Input_Data[5].3 CH2_Forward
3
SM2_Input_Data[5].7 CH2_Fault
4
SM2_Input_Data[5].8 CH2_At_Speed
This rung displays the Feedback from the drive. An integer represents the xxx.x Hz format (decimal is implied) used by the
drive, so a displayed value of "300" equates to 30.0 Hz.
5
Move
Source SM2_Input_Data[6]
200
Dest CH2_Feedback
200
MOV
The following rungs display some of the Logic Command bits sent to the drive. Refer to Appendix D in the 1769-SM2 user
manual for additional information about the Logic Command word.
6
CH2_Stop SM2_Output_Data[3].0
i
This rung unlatches the contact that turns on the Start command when the drive is not communicating with the 1769-SM2.
This prevents the drive from immediately starting when communications are restored. If an immediate start is desired for an
application, this rung could be deleted.
7
/
CH2_Valid_Data
<SM2_Input_Data[2].5>
U
CH2_Start
i
8
CH2_Start SM2_Output_Data[3].1
9
CH2_Jog SM2_Output_Data[3].2
10
CH2_Clear_Fault SM2_Output_Data[3].3
Vista de pagina 146