Appendix B
Module Parameters
Appendix B provides information about the 1769-SM2 module parameters.
The parameters in the module are numbered consecutively.
Topic Page
About Parameter Numbers
B-1
Parameter List B-1
About Parameter Numbers
Configuration Tool Numbering Scheme
DriveExplorer The module parameters begin with parameter 01. For
example, Parameter 01 - [Config Mode] is parameter 01
as indicated by this manual.
DriveExecutive
HIM
TIP: All module parameters—except Parameters 01 - [Config Mode],
02 - [DSI Mode], and 03 - [Reset Module]—are grouped by channel
number. The respective channel number is shown at the end of the
parameter name (for example, Parameter 04 - [Idle Action 1] for CH1).
Parameter List
Parameter
No. Name and Description Details
01 [Config Mode]
Displays the module’s configuration mode
(Controller or Parameter) set with the
Configuration Mode Switch (SW1 in Figure 2.1
).
Default: 0 = Controller
Values: 0 = Controller
1 = Parameter
Type: Read Only
02 [DSI Mode]
Displays the module’s operating mode (Single or
Multi-Drive) set with the Operating Mode Switch
(SW2 in Figure 2.1
).
Default: 0 = Single
Values: 0 = Single
1 = Multi-Drive
Type: Read Only