Defining Fault Action 91
.
Disable Drive:
Feedback is disabled.
The controller cannot command motion.
Motion on the axis depends upon your hardware configuration. Some
hardware configurations may require brakes.
Stop Motion:
Feedback remains enabled.
The controller continues to be able to command motion.
Motion stops at 100% of the Maximum Deceleration rate (set in the
Dynamics page of the Configure Axis dialog box).
Status Only:
Feedback remains enabled.