Rockwell-automation GMLC Reference Manual Manual de usuario Pagina 792

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 958
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 791
Publication GMLC-5.2 - November 1999
Defining Inputs and Outputs 755
Defining Inputs and Outputs
After you have enabled the CNET interface (see Enabling the CNET
Interface in GML Commander), you need to define:
MAC ID
Input bits
Input floats (floating point variables)
Input group bits
Output bits
Output floats (floating point variables)
Output group bits
Defining the I/O Configuration
To define the I/O Configuration:
1. From the menu bar, select Configure. The Configure menu appears.
2. Select Control Options. The Configure Control Options dialog box
appears.
3. Select the CNET tab. The CNET page appears.
Note: If no CNET tab appears, on the General page of the Control
Options dialog box, select IMC S Class 1394/1394 Turbo in
the Control Type field, 3.9 (or higher) in the iCODE Version
field, and the CNET field in the Interface area (see Enabling
the CNET Interface in GML Commander). Then select the
CNET tab.
Vista de pagina 791
1 2 ... 787 788 789 790 791 792 793 794 795 796 797 ... 957 958

Comentarios a estos manuales

Sin comentarios