Rockwell-automation GMLC Reference Manual Manual de usuario Pagina 838

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 958
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 837
Publication GMLC-5.2 - November 1999
Understanding M Files 801
Note: The number of M0 and M1 words specified above should
match the number of words set in the SPIO section of your
SLC 500 program software.
5. Select OK.
6. Define your M0 Floats. See Defining M0 Floats.
Defining M0 and M1 Floats and Integers
The procedures for defining M0 Floats, M0 Integers, M1 Floats and M1
Integers are virtually identical. In each case, you create a variable—or an
array of variables— using the same dialog box (except for the dialog
box’s name).
But, as you define these variables, remember:
M1 Floats and M1 Integers transfer data from the 1394 GMC Turbo
to the SLC.
M0 Floats and M0 Integers transfer data from the SLC to the 1394
GMC Turbo.
To define M0 and M1 floats and integers:
1. In the Tag Explorer, select the type of variable.
2. In the Tag Window, single-click the right mouse button. A variable
short-cut menu appears.
3. Select New. The appropriate dialog box appears. For example, the
SLC M0 Float dialog box appears below.
Vista de pagina 837
1 2 ... 833 834 835 836 837 838 839 840 841 842 843 ... 957 958

Comentarios a estos manuales

Sin comentarios