Publication GMLC-5.2 - November 1999
594 Status Variables
Axis Module Fault Status 1394
Axis_module_fault_status_1394 is an integer value representing the
highest priority fault condition currently active in the axis module. The
table below shows the 1394 Axis Module Fault Status values, and the
corresponding message that appears in an Axis Fault field in the runtime
display (if enabled).
In the Tag Explorer select both Axis System Variables and the desired
physical axis, then select System_module_fault_status_1394 in the Tag
Window.
System Smart Power I Limit Status 1394
System_smrt_pwr_i_limit_status_1394 is a logical (Boolean) variable,
with a value of:
Fault Value Description Runtime Display
11 Ring Fault RNG FLT
10 Not Installed NO AXIS
9 Axis_bus_loss_fault_1394 BUS FLT
8 Axis_power_fault_1394 PWR FLT
7 Axis_it_fault_1394 It FLT
6 Axis_Motor_over_temp_fault_1394 TMP FLT
5 Motor_Thermal_1394 MTR FLT
4 Position_error_fault ERR FLT
3 Hardware_overtravel_fault HRD FLT
2 Software_overtravel_fault SFT LIM
1 Encoder_loss_fault or
Encoder_noise_fault
ENC FLT
0 No Faults AXIS OK