Publication GMLC-5.2 - November 1999
598 Diagnostic Variables
In the Tag Explorer select General System Variables, then select
Analog_test_output_0_1394 in the Tag Window.
If you set the Analog_Test_0_Mode_1394 data parameter to 0 (using a
Control Settings block with Adjust selected), you can also assign this
variable a value (using an Equation block with Configured selected) that
is converted to an equivalent voltage on the A_TEST_0_output_1394.
The voltage range of this output is -10 to +10 Volts.
The A_TEST_0 output is one of two analog outputs provided for
diagnostic purposes.
Analog Test Output 1 1394
The Analog_test_output_1_1394 variable reports the current voltage
being generated by the 1394 analog output A_TEST_1.
In the Tag Explorer select General System Variables, then select
Analog_test_output_1_1394 in the Tag Window.
Analog
Test 0 Mode 1394
(D99)
Analog Test 0
Axis 1394
(D101)
Analog Test
Output 1394
(System Diagnostic Variable)
0 = Generic N/A User-assigned value (converted to equivalent
output voltage to output A_TEST_0)
1 = Velocity 0 – 3 Voltage representation of output A_TEST_0 (1 volt
= 1 KRPM)
2 = Torque 0 – 3 Voltage representation of output A_TEST_0 (1 volt
= 40% Rated Torque)