Publication GMLC-5.2 - November 1999
Adjusting Gains Values for the Servo Axis 111
Adjusting Gains Values for the Servo Axis
The Adjust Gains dialog box is accessible only if the start-up (offline)
gain values and the working (online) gain values are identical.
Equalizing the Working and Set-up Gains Values
You must be online to set the working and the setup gain values equal to
each other. To set the values, do one of the following:
On the Apply page of the Configure Axis Use dialog box, select
Upload or Download (depending upon the version of the axis use
configuration you want to use).
On the General page of the Control Options dialog box, select
Download Axis/Drive. The current application program is
downloaded.
Adjusting Gains
You can use the Adjust Gains dialog box to:
Make incremental changes to working gain values, start-up gain
values, or both.
Start, stop, or kill the program, as needed, as you fine-tune the gain
values.
These digitally-set gain values provide software control over the servo
dynamics and allow the servo system to stabilize.
!
ATTENTION: The Up and Down buttons immediately
affect the control’s gains. Some gains values can cause
unpredictable motion. Keep clear of dangerous moving
machinery.