Publication GMLC-5.2 - November 1999
Show Axis Status 351
In the above table, the columns at the right show whether each status
value is valid for servo (S), master only (MO), virtual (V), or imaginary
(I) axes.
Axis Status Values
Status
Value Description
Runtime
Display S
M
OVI
14 AxisLink Timeout AXL FLT
13 AxisLink Failed (axis not fount) AXL FLT
12 Virtual Axis Not Enabled AXS OFF
11 Drive Fault DRV FLT
10 Position Error Tolerance Fault ERR FLT
9 Hardware Overtravel Fault HRD LIM
8 Software Travel Limits Fault SFT LIM
7 Encoder Noise or Loss Fault ENC FLT ✔✔
6 Feedback OFF or SRV OFF ✔✔
Virtual Axis Enabled SRV OFF
5 Servo Output Limited OUT LIM
4 Homing HOMING ✔✔
3 Moving or
Executing Time-Lock Cam MOVING ✔✔
2 Jogging JOGGING ✔✔
1 Axis Unlocked UNLOCK ✔✔
0 Axis Locked LOCKED