Publication GMLC-5.2 - November1999
581
Position Lock Cam Pending Profile Status
PCAM_pending_profile_status is a logical (Boolean) variable which has
values of:
• 1 (true) if a new position-lock cam profile is currently pending for the
axis
• 0 (false) if not
In the Tag Explorer, select both Axis System Variables and the desired
physical or imaginary axis, then select PCAM_pending_profile_status in
the Tag Window.
Pending position-lock cams are set up by choosing Pending Position-
Lock from the Cam Type pop-up menu in the Configure Cam block.
Position Lock Cam Auto-Correction Status
PCAM_auto_correction_status is a logical (Boolean) variable which has
values of:
• 1 (true) if auto-correction is currently enabled on the specified axis
• 0 (false) if not
.
Master Position
Current
Profile
New
Profile
Slave Position
PCAM_pending_
profile_status
Pending (New)
Position-Lock Cam
Configured