Publication 1394-IN024B-EN-P — February 2004
Commissioning Your 1394 SERCOS Interface System 1-11
Configuring Your Logix
SERCOS interface Module
This procedure assumes that you have finished wiring your 1394
SERCOS interface system and have finished configuring the 1394
system module switches.
For greater detail on the RSLogix 5000 software as it applies to
ControlLogix and SoftLogix modules, refer to the table below for the
appropriate publication.
If you have already configured your Logix module using one of the
setup and configuration manuals listed above, go directly to Applying
Power to the 1394 SERCOS interface System (page 1-20). If not, go to
Configuring Your Logix Controller beginning below.
Configuring Your Logix Controller
To configure your Logix controller:
1. Apply power to your Logix chassis/PC containing the SERCOS
interface module and open your RSLogix 5000 software.
2. Select New in the File menu. The New Controller window opens.
Select controller type
Name the file
Select the ControlLogix chassis size
Select the ControlLogix processor slot
3. Select OK.
4. Select Controller Properties in the edit menu. The Controller
Properties window opens.
For: Refer to this Document Publication Number:
Detailed information on configuring and
troubleshooting your ControlLogix motion module
ControlLogix Motion Module
Setup and Configuration Manual
1756-UM006x-EN-P
Detailed information on configuring and
troubleshooting your SoftLogix PCI card
SoftLogix Motion Card Setup and
Configuration Manual
1784-UM003x-EN-P