Publication 1394-IN024B-EN-P — February 2004
Commissioning Your 1394 SERCOS Interface System 1-17
Configuring the Motion Group
To configure the motion group:
1. Right-click Motion Groups in the explorer window and select New
Motion Group. The New Tag window opens.
2. Name new motion group.
3. Select OK. New group appears under Motion Groups folder.
4. Right-click on the new motion group and select Properties. The
Motion Group Properties window opens.
5. Select the Axis Assignment tab and move your axes (created
earlier) from Unassigned to Assigned.
6. Select the Attribute tab and edit the default values as appropriate
for your application.
7. Select OK.