
Rockwell Automation Publication 20COMM-UM015B-EN-P - July 2013 115
Using Explicit Messaging Chapter 6
ControlLogix Controller Example Scattered Read Response Data
The Scattered Read Request message reads the multiple parameters and returns
their values to the destination tag (Scattered_Read_Response). Figure 42
or
Figure
shows the parameter values.
Figure 42 - Example Scattered Read Response Data for PowerFlex 7-Class Drive
In this message example, the parameters have the following values.
PowerFlex 7-Class Drive Parameter Read Value
1 - [Output Freq] 32.5 Hz
3 - [Output Current] 0.01 Amp
6 - [Output Voltage] 118.7 VAC
12 - [DC Bus Voltage] 329.2 VDC
17 - [Analog In2 Value] 8.318 mA
Comentarios a estos manuales