220 Rockwell Automation Publication 20COMM-UM015B-EN-P - July 2013
Appendix D Logic Command/Status Words
Logic Command Word (Control)
Bit # Status Description
1514131211109876543210
X Stop 1 — Stop/Inhibit
0 — No Action
X Start 1 — Start
0 — No Action
XOption #1
Input
1 — Stop Maneuver/Inhibit
0 — No Action
X Clear Faults 1 — Clear Faults
0 — No Action
XOption #2
Input
1 — Perform Option 2 function
0 — No Action
— — Bits 5…10 — Not Used
X Aux Enable 1 — Use Aux 1…Aux 4
0 — Ignore Aux 1…Aux 4
X Aux 1 1 — Aux 1 Active
0 — Aux 1 Inactive
X Aux 2 1 — Aux 2 Active
0 — Aux 2 Inactive
X Aux 3 1 — Aux 3 Active
0 — Aux 3 Inactive
X Aux 4 1 — Aux 4 Active
0 — Aux 4 Inactive