Rockwell-automation 2092-DAx Ultra1500 Host Commands for Serial Commun Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
1 Publication 2092-RM001A-EN-P — March 2005
Chapter
2
Command Reference
This chapter defines the values that are valid for each Ultra1500 Host
Command. The commands are grouped into the following sections:
General Commands
Parameters
Group 0, Basic drive system and I/O settings
Group 1, Gain and gain tuning settings
Group 2, velocity control settings
Group 3, Position control settings
Group 4, Torque control settings
Group 5, Supplementary drive system and I/O settings
Group 6, Supplementary gain settings and fault reports
Group 7, Motor and drive operating mode parameters
General Commands
Read Parameter (SET)
Command: SET
Description: Read parameter value
Format: STX ID # SET PPP : BSS ETX
Data: Argument Description
PPP Parameter #; (e.g., [Pr-2.03], PPP=203=0x0CB)
Refer to Parameters beginning on page 2-14 for
a description of available parameters.
Response Format: STX ID $ SET V : BSS ETX
Response Data: Argument Description
V Parameter value, 4 or 8 bytes signed
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 69 70

Comentarios a estos manuales

Sin comentarios