Rockwell-automation 2092-DAx Ultra1500 Host Commands for Serial Commun Manual de usuario Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
Publication 2092-RM001A-EN-P — March 2005
2-46 Command Reference
[Pr – 9.58] Oscilloscope Configuration
[Pr – 9.59] Oscilloscope Scaling
Ultraware Name: Scope Config
Data Size: 21 digits
Value Description
0 to 1 Channel A Signal
See Monitor Variables on page A-3 for a list
of variables.
2 to 3 Channel B Signal
See Monitor Variables on page A-3 for a list
of variables.
4 Channel A Signal
0 = Auto (default)
1 = Manual
5 Channel B Scale Type
0 = Auto (default)
1 = Manual
6 to 7 Sample Period
8 to 9 Samples per Division
10 to 12 Trigger Signal
See Monitor Variables on page A-3 for a list
of variables.
13 Trigger Mode
14 Pretrigger, %/1
15 to 22 Trigger Threshold
Default:
0x00000000000000000000000000000000
Operating Mode: All
Data Size: 32 digits
Value Description
0 to 7 Channel A Scale
8 to 14 Channel A Offset
15 to 23 Channel B Scale
24 to 31 Channel B Offset
Default:
0x00000000000000000000000000000000
Operating Mode: All
Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 69 70

Comentarios a estos manuales

Sin comentarios