Rockwell-automation FlexPak 3000 Power Module SW-Version 4.3 Manual de usuario Pagina 171

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 216
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 170
APPENDIX D
49’1340 e FlexPak 3000 D-1
KEYPAD
*TERMBLK
NETWORK
Keypad Stop Signal
Terminal Block Stop Signal
Network Stop Signal
OIM Run Signal
Terminal Strip Run Signal
Network Run Signal
Keypad Test Mode Enable Signal
Keypad Jog Signal
Terminal Block Jog Signal
Network Jog Signal
Keypad Forward/Reverse Signal
Terminal Block Forward/Reverse Signal
Network Forward/Reverse Signal
Keypad Fault Reset Signal
Terminal Block Fault Reset Signal
Network Fault Reset Signal
Keypad Auto/Manual Signal
Terminal Block Auto/Manual Signal
Fixed Auto Mode Signal
Stop Request
Keypad Stop Request
P.000 Control Source Select
Run Request
Test Mode Enable Request
Jog Request
Current Limit Stop Command
To Speed Reference Ramp
and Mode Select Block Diagram
s
To Speed Reference Mode
Select Block Diagram
To CML Reference
Block Diagram
To Speed Reference Mode
Select Block Diagram
To Speed Reference Mode
Select, CML Reference, and
CML Block Diagrams
To Speed Reference Mode
Select Block Diagram
To Fault Processing
Ramp Stop Command
Jog Command
Jogging Active
Drive Test Mode
Debounced Jog Request
S
E
Q
U
E
N
C
I
N
G
Note: When configured as a current regulator (J15),
Control Source Select can only be set to TERMBLK
or NETWORK.
Fault Reset Command
* = Default Selection
To Speed Reference
Ramp and Mode Select
Block Diagrams
Fixed Forward Direction Signal
REVERSE DISABLE
Forward/Reverse Command
*OFF
ON
P.015
To Speed Reference Souce
Select and Mode Select
Block Diagrams
*SPD
(speed/voltage regulator)
CUR
(current/torque regulator)
(J15 REGULATOR TYPE)
Hardware Jumper REG TYPE
Auto/Manual Command
P.799
SERIAL
Serial Stop Signal
Serial (HOST) Stop Request
Serial Run Signal
KEYPAD
*TERMBLK
NETWORK
SERIAL
P.000 Control Source Select
P.000 Control Source Select
P.000 Control Source Select
P.000 Control Source Select
P.000 Control Source Select
KEYPAD
*TERMBLK
NETWORK
SERIAL
KEYPAD
*TERMBLK
NETWORK
SERIAL
Serial Test Mode Enable Signal
No Connection
Serial Jog Signal
KEYPAD
*TERMBLK
NETWORK
SERIAL
Serial Forward/Reverse Signal
KEYPAD
*TERMBLK
NETWORK
SERIAL
Serial Fault Reset Signal
KEYPAD
*TERMBLK
NETWORK
SERIAL
Serial Port Auto/Manual Signal
Network Auto Mode Signal
P.000 Control Source Select
Figure D.1 - Drive Control Signals
Vista de pagina 170
1 2 ... 166 167 168 169 170 171 172 173 174 175 176 ... 215 216

Comentarios a estos manuales

Sin comentarios