APPENDIX G
FlexPak 3000 49’1340 e
G-8
Table G.1 - User Quick Reference Table for Input Parameters (continued)
Par.
Parameter Parameter Selection / Pg Initial Factory User Data
No.
Adjustment Range B- Setting Date Setting
808 OCL PI PROP GAIN 0.10 - 128.00 39 2.00
809 OCL PI LEAD FREQ 0.00 - 141.37 rad/s 38 1.00 rad/s
810 OCL PI POSITIVE LIMIT 0 - 100% of TOP SPEED 39 100%
811 OCL PI NEGATIVE LIMIT 0 - 100% of TOP SPEED 38 100%
812 OCL TRIM RANGE -100 - 100.0% 40 0.0%
813 OCL PROP TRIM SELECT
1 = DISABLED
2 = ENABLED
39 1
814 OCL TYPE3 POSN REG EN
1 = DISABLED
2 = ENABLED
41 DISABLED
Network Communication
900
(1)
NETW DROP NUMBER 1 - 55 if
NETW CONNECT TYPE=BASIC
1 - 52 if
NETW CONNECT TYPE = FULL
35 1
901
(1)
NETW COMM LOSS SELECT
FAULT
HOLD LAST REF
USE TRMBLK REF
35 FAULT
902 NETW OUT REG 1 SELECT -32768 - 32767 35 0
903 NETW OUT REG 2 SELECT -32768 - 32767 35 0
904 NETW OUT REG 3 -32768 - 32767 36 0
910
(1)
NETWORK CONNECT TYPE
BASIC
FULL
35 BASIC
911
(1)
AMX NETW REF SELECT
DIRECT
BROADCAST n (n=1-8)
1 DIRECT
912
(1)
NETWORK BAUD RATE
0.0 Kbaud
125.0 Kbaud
250.0 Kbaud
500.0 Kbaud
34 0.0 Kbaud
913
(1)
DEVICENET POLL MSG
CONTROL ONLY
CONTROL + CONFIG
11 CONTROL
ONLY
914 NETW REGISTER MAP SEL
1 = ORIGINAL
2 = ALTERNATE
36 1
915 CNI PROG/RUN MODE
1 = STOP
2 = NOT STOP
10 STOP
SPEED FEEDBACK GAIN
(
Alternate network map,
Drop_1, reg. 38)
1000 – 32 000 46 1000
SPD LOOP PI INIT SEL
(
Alternate network map,
Drop_2, reg. 32)
0 = ZERO
1 = SPD LOOP PI INIT VAL
2 = ANALOG MAN TRIM REF
47 0
SPD LOOP PI INIT VAL
(
Alternate network map,
Drop_1, reg. 39)
-32768 - 32767 48 0
SPD LOOP PI RESET
(
Alternate network map,
Drop_1, reg. 32, bit 6)
0 = OFF
1 = ON
48 0
UNDERWIND ENABLE
(
Alternate network map,
Drop_1, reg. 32, bit 5)
0 = DISABLED (overwind)
1 = ENABLED (underwind)
52 1
(1) Parameter is only available or displayed on the OIM if an optional Network Communications board is installed.