114 Rockwell Automation Publication 2098-UM001G-EN-P - February 2011
Chapter 3 Configuring the Ultra3000 Drive
Logic Command Mask Specifies the digital inputs functions that can be overridden.
Check the items that can be overridden. The digital input
functions are:
Define Home
Define Position
Disable Serial Communications
Drive Enable
Fault Reset
Follower Enable
Integrator Inhibit
Operation Mode Override
Pause Homing
Pause Index
Position Strobe
Preset Select 0
Preset Select 1
Preset Select 2
Preset Select 3
Preset Select 4
Preset Select 5
Remove Command Offset
Reset Drive
Start Homing
Stop Indexing
Stop Homing
Start Indexing
Enable Behavior Drive enable logic configuration. The options are:
Hardware OR DNet Input
Both
Change of State Mask The change of state mask is used with change of state I/O
messaging. If a particular option is selected in 'Change of State
Mask', then a change of state I/O message is produced
whenever the corresponding bit in the I/O message changes
value. Otherwise, a change of state I/O message is not
produced. Check the options that should generate change of
state I/O messages:
At Home
At Index 0 Position
At Index 1 Position
Axis Homed
Brake
DC Bus Charged
Drive Enabled
End of Sequence
In Motion
In Dwell
In Position
Negative Current Limit
Negative Hardware Overtravel
Negative Software Overtravel
Position Compare 1/Write Data Error
Position Compare 2/Write Data Busy
Positive Current Limit
Positive Hardware Overtravel
Positive Software Overtravel
Ready
Registered
Startup Commutation Done
Tracking
Up to Speed
Within Position Window
Within Speed Window
Zero Speed
Parameter Description