176 Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Chapter 6 Specifications
Standards Compliance and Certifications
UL/CSA EN/IEC Other Agencies
Standards Compliance
UL 508C Power Conversion Equipment –
Suitable for Group Installation
CSA C22.2, No. 14
EN 61800 - Adjustable Speed Electrical
Power Drive Systems, Part 3: EMC
Requirements and Specific Test Methods,
CE Marked per EMC Directive 2004/108/EC,
Part 5-1: Safety Requirements – Electrical,
Thermal and Energy, CE Marked per Low
Voltage Directive 2005/95/EC
CCC (Pending)
KCC
C-Tick
ODVA for EtherNet/IP and DeviceNet
Certifications cULus (File No. E207834, Guides NMMS, NMMS7)
Communication Ratings
Rated Insulation Voltage 250V
Operating Dielectric Withstand UL/NEMA: 1500V AC, IEC: 2000V AC
DeviceNet
DeviceNet Supply Voltage Rating Range 11…25V DC, 24V DC nominal
DeviceNet Input Current 50 mA @ 24V DC
DeviceNet Input Current Surge 500 mA peak inrush
Baud Rates 125, 250, 500 kbps
Distance Maximum
500 m (1630 ft) @ 125 kbps
200 m (656 ft) @ 250 kbps
100 m (328 ft) @ 500 kbps
Auto-Baud Rate Identification Yes
"Group 2 - Slave Only" Device Type Yes
Polled I/O Messaging Yes
Change of State Messaging Yes
Cyclic Messaging Yes
Explicit Messaging Yes
Full Parameter Object Support Yes
Group 4 - Off-Line Node Recovery Messaging Yes